Featured Products

Highest quality standards are achieved through the implementations of latest technology, decades of experience and everlasting moral values , which have helped us to retain our customers as well as multiply them.

Welcome to APPLICATION CONTROL PANELS P.LTD.

H.T. Switchyards

  /> </div>
<div class=

Our experienced  team is capable for compliance of the respective state electrical norms and execute the project in time.

We have successfully executed many projects. To name a few 
NHK Springs India Ltd , Manesar, Gurgaon in 2010. 

Defence Project, Lonavala , Maharastra in 2011.
Zimdra Foods Ltd at Bhutan  in 2012.
KLJ Reality, Faridabad in 2014.
NHK Springs India Ltd Sricity, Nellure, Andhra Pradesh in 2015.

Yakult Danone India Pvt Ltd, Rai Sonepat,Haryana  in 2015, 
and many more……..

Power Control Center Panel (P.C.C.)

  /> </div>
<div class=

This is the first point where power comes from Transformer and DG.Here circuit resistance is very low, which results in highest fault level. PCC panel must have proper fault level calculation. Bus bar, support, cooling and switchgear should be designed accordingly. Form (3,4) design help forman power safety and optimum utilisation of the system.We also give different colour codingen closure for electricity board/ DG and bus coupler for better understanding for the operator.
 

Technical Specifications

  • Enclosure : Fabricated with 1.6/2 mm CRCA sheet and 3 mm sheet for Gland Plate with Bus duct flange and ample care for top/bottom termination, cable tie arrangement.
  • Rated Current : Upto 6300 Ampere Aluminium or Copper main bus bar. Operational Voltage.
  • Frequency :  380/415/440/690 Volt at 50/60 Hz, 3 Phase, 4 wire system.
  • Short Circuit Level : 35KA/50KA/70KA/100KA for 0.5/1/3 second.
  • IP Protection : Our CPRI Bhopal certification gives locational advantage like Indoor/ outdoor
  • Automation : Smart system gives information to decision makers for strategy and analysis.

Motor Control Centre Panel (M.C.C.)

  /> </div>
<div class=

MCC receive power from PCC panel and  give power to different section of Plant / building or places. This comprise of ACB, MCCB, MPCB, protection and measuring relays  based on type of industry and application.  Implementation of Log out Tag out ( LOTO)   gives additional  safety to users.  Tripping sequence  setting of circuit breakers give immense satisfaction for  avoiding wrong  feeder tripping  and chance of cascade tripping.
 

Technical Specifications

  • Enclosure:- Fabricated with 1.6/2 mm CRCA sheet and 3 mm sheet for Gland Plate with Bus duct flange and ample care for top/bottom termination, cable tie arrangement.
  • Rated Current:- Upto 6300 Ampere Aluminium or Copper main bus bar. Operational Voltage.
  • Frequency :- 380/415/440/690 Volt at 50/60 Hz, 3 Phase, 4 wire system.
  • Short Circuit Level:- 35KA/50KA/70KA/100KA for 0.5/1/3 second.
  • IP Protection:- Our CPRI Bhopal certification gives locational advantage like Indoor/ outdoor
  • Automation:- Smart system give information to decision makers for strategy and analysis.

Automatic Power Factor Control Panel (A.P.F.C.)

  /> </div>
<div class=

Perfect power factor is required  not only to save electricity charges but for better economisation of  cable   and  other current   flowing  equipment.  Our strong Application experience helps us to design the Automatic Power Factor Panel (APFC) based on type of load and  load cycle.  We manufacture thyristor based or contactor based  panel with  7% to 14 % reactor to suit the application. Proper enclosure and selection of switchgear is critical for charging and discharging of capacitors.

Automation And Variable Frequency Drive Panel (V.F.D.)

  /> </div>
<div class=

We understand VFD very well  so we also take care of heat dissipation while designing these panels for better life of VFD and less cost of air-conditioning for long and trouble free operation. We have reduced  air-conditioning cost in several power co-generation projects, by special panel designing .

Weather Proof Panel

  /> </div>
<div class=

When outdoor panels are to be manufactured special precaution has to be taken keeping in mind the exposure to the harsh external conditions.These panels  had dual sheet wall filled with Rockwool for thermas action.  Smart control understand weather and allow system to run. We have IP 55  approval from CPRI Bhopal for indoor as well as outdoor type panels .

 Our Weather Proof Panels are working successfully in Ladhak at -25 degree centigrade tempratures.

Bus Ducts And Rising Mains

  /> </div>
<div class=

Now a days almost all electricity boards are encouraging the use of bust duct above 1000 Amp  between Transformer and main panel instead of connections through cables. This is designed in IP 32 or IP 65 indoor or outdoor based as per the transformer's location. Air insulated bus duct is dust and vermin proof  with Aluminium or Copper conductor. it comes in segregated or non-segregated versions.  Flexible copper connection is required at transformer or DG section because bus duct is static equipment .

D.G. Synchronisation Panel

  /> </div>
<div class=

Our vast automation experience give us technical edge over other fellow panel manufacturers for power management . We give good blend of PLC and DEIF relays for DG synchronisation for multiple DG and multiple choice of auto or manual run systems. Most of the features can be seen and controlled from single console. Person sitting anywhere in the world can monitor and control these systems.

Control And Relay Panel

  /> </div>
<div class=

Control and Relay Panel receive power from PCC panel and give power to different section of Plant / building or locations. This comprises of ACB, MCCB, MPCB, protection and measuring relays based on type of industry and application. Implementation of Log out Tag out ( LOTO)  gives additional safety to users. Tripping sequence setting of circuit breakers gives immense satisfaction for avoiding wrong feeder tripping and chance of cascade tripping.
 

Technical Specifications

  • Enclosure : Fabricated with 1.6 /2 mm CRCA sheet and 3 mm sheet for Gland Plate with Bus duct flange and ample care for top/bottom termination, cable tie arrangement.
  • Rated Current : Upto 6300 Ampere Aluminium or Copper main bus bar. Operational Voltage.
  • Frequency : 380/415/440/690 Volt at 50/60 Hz, 3 Phase, 4 wire system.
  • Short Circuit Level : 35KA/50KA/70KA/100KA for 0.5/1/3 second.
  • IP Protection : Our CPRI Bhopal certification gives locational advantage like Indoor/ outdoor protection.
  • Automation : Smart system gives information to decision makers for strategy and analysis.

Industrial Automation And Machine Vision System

  /> </div>
<div class=
  • Digital read out system (DRO) :  Dial, LVDT or Varnier  and load cell.
  • Vision system for  gear inspection machine.
  • High speed bar code system with Traceability solution through Cognex /Leuze
  • Safety system : Safety curtain , Safety switch, Area sensor,Hard key  safety
  • Sensors, VFD, PLC , HMI  and motors.
  • Thermo Plastic  IP 67 rating enclosures

Our Vision

* To embrace new technologies and methods. * To give unsurpassed products and services to the clients. * To constantly look for improvement and changes.

Site Designed & Maintained by Aman Infotech
Automatic Power Factor Control Panel (A. P. F. C, Automation And Variable Frequency Drive Panel (V. F. D, Automation Equipment, Automation Systems, Bus Ducts And Rising Mains, Capacitor Panels, Control And Relay Panel, Control Equipment, Control Panels, D. G. Synchronisation Panel, Electrical Control Panels, Electronic Indicators, H. T. Switchyards, Industrial Automation And Machine Vision System, Industrial Automation Systems, Ir Control Panel, Motor Control Centre Panel (M. C. C, Power Control Center Panel (P. C. C, Weather Proof Panel